Resynchronizing with a Time Server

If you find that the clock on your domain-joined Windows 7 computer has the incorrect time, you can troubleshoot the problem and resynchronize with your NTP server as follows. Begin by opening an admin-level command prompt and typing w32tm /query /status to display which server your computer is getting its time from:

C:\Users\Administrator.FABRIKAM>w32tm /query /status

Leap Indicator: 0(no warning)
Stratum: 2 (secondary reference – syncd by (S)NTP)
Precision: -6 (15.625ms per tick)
Root Delay: 0.0624001s
Root Dispersion: 0.0100000s
ReferenceId: 0x564D5450 (source IP: 86.77.84.80)
Last Successful Sync Time: 6/10/2010 9:36:20 AM
Source: VM IC Time Synchronization Provider
Poll Interval: 10 (1024s)

Here the Windows 7 computer is a virtual machine running on a Hyper-V host, and for some reason the time on the host is set incorrectly.

Now type w32tm /resync /rediscover to force a new time synchronization with the configured time server for the domain:

C:\Users\Administrator.FABRIKAM>w32tm /resync /rediscover

Sending resync command to local computer
The command completed successfully.

Run the w32tm /query /status command again to see where the time is now coming from:

C:\Users\Administrator.FABRIKAM>w32tm /query /status

Leap Indicator: 0(no warning)
Stratum: 3 (secondary reference – syncd by (S)NTP)
Precision: -6 (15.625ms per tick)
Root Delay: 0.0312500s
Root Dispersion: 7.8170376s
ReferenceId: 0xAC100B0A (source IP: 172.24.11.10)
Last Successful Sync Time: 6/10/2010 10:07:09 AM
Source: NYC-DC-01.fabrikam.com
Poll Interval: 10 (1024s)

Your computer's time is now coming from the domain controller in the Fabrikam domain as expected.